Installation of underfloor heating is possible in rooms with high ceilings. Most often they are mounted in the bathroom, but underfloor heating can be installed throughout the apartment.
There are several heating methods that you need to choose individually, depending on the height of the ceilings, the condition of the wiring and the pressure of the water in the apartment or country house. The most popular are heating mats, which are easy to install.
In this article, we examined the basic rules for laying infrared and cable underfloor heating. They also gave a detailed briefing on the arrangement of the heating system for tiles using heating mats. The material is equipped with step-by-step photos and video recommendations of specialists in laying warm floor.
Varieties of underfloor heating
Before you start choosing a floor heating system, you need to consider that they have limitations. Despite the fact that the heating systems are able to completely replace the heating in the apartment, this cannot be done according to the norms of Russian legislation.
These limitations are caused by a number of reasons:
- In apartments it is allowed to use only electric underfloor heating, and the massive use of such systems in the house leads to an increase in the load on the electric network.
- Massive or partial transition to electric heating leads to an imbalance in the heat supply system in the house.
Since the floor will not be used as the main source of heat in the apartment, you can save on its installation. The saving is to lay a heating cable or film only in places that are free of furniture.
This will reduce the consumption of thermal energy, which will make it more economical in the long term, as well as at the same time, when purchasing building materials and installation
In a private house, the possibilities of applying this technology are much wider. Depending on the available energy sources, you can choose an acceptable option between water and electric heating.
If the house is equipped with autonomous sources of electricity, such as wind generators or solar panels, it is undoubtedly worth making a choice in favor of electric, i.e. cable or infrared heating systems.
If electricity is supplied through power lines, then the use of the electric option for heating a private house will be very expensive. In that case, it is better to opt for a warm water floor. It will last about 35 years, after which it will require replacement.
Image Gallery
Photo from
Reasons for installing underfloor heating under tile
Construction of an electrical cable system
Fastening the heating cable in the construction of a warm floor
Electric heating mat with thermostat
Infrared heating system
Water floor heating pipeline
Organizations in the use of aquatic varieties
Water system header
Basic rules for installing underfloor heating
Despite the different principle of heating, there are several basic principles for installing all types of underfloor heating under the floor tiles.
The first general rule is to remove the old screed after directly dismantling the coating. This will allow you to win a few centimeters of the height of the room, which is especially true in apartments with low ceilings or if the heater is mounted in only one room.
The second basic rule is surface alignment. Any cavity or bulge over time will remove and build a warm floor. All debris must be removed and slots and pits covered. Only then can you start waterproofing
For waterproofing, you can use special compounds, such as water glass or bitumen. Particular attention should be paid to bathrooms. If moisture gets through the screed, this will lead to the gradual destruction of concrete. This is true for private homes and apartments.
After waterproofing, you need to make thermal insulation. Its thickness is determined individually, depending on the height of the ceilings and the level of the difference in pilaf between rooms. The thinner the insulation layer, the greater the heat loss.
This will inevitably increase energy consumption for floor heating. In the case of installing floors with an electric type of heating, the absence of thermal insulation will cause premature production of equipment resources
Another rule is the need to reinforce the floor under the tiles.
For this, ready-made reinforced meshes with a wire thickness of not more than 6 mm are used.
This is necessary to strengthen the screed and prevent its cracking. Fragments of a reinforced mesh are knitted together by knitting wire.
Mixtures with gypsum base cannot be used for pouring floor screed under the tile. They are too fragile and not suitable for pressure. In addition to fragility, they do not possess the properties necessary for adhesion to tile adhesive.
It is necessary to use leveling mixtures such as bulk floors. They give the best effect, since the surface is smooth and suitable for laying tiles with a minimum consumption of adhesive.
Rules for laying cable underfloor heating
Before installing new equipment, which will create a load on the wiring in an apartment or house, you need to make sure that the wiring can withstand it. First you need to make a markup where the electric mats will lie.
When planning in an apartment, it is necessary to exclude laying in the locations of permanently installed large furniture without legs, plumbing fixtures and household appliances. This is due to the fact that electricity creates a magnetic field, which will interfere with household appliances.
You can not lay the underfloor heating under the tiles where the bathroom, bath and shower are installed. In these areas, there is a high risk of moisture and short circuiting.
When planning, it is also impossible to lay electric heating in the locations of water and gas pipes.
Determination of power, cable cross-section and wiring in the house
The minimum distance from each wall should be at least 10 cm. It is also necessary to exclude areas where furniture is installed. The area for installing mats is calculated by subtracting the total square meters from the total area where installation will not be carried out.
The resulting number must be multiplied by 140 watts if the floor will not be used as the main source of heat. If you plan to use only the floor for heating, then you need to multiply by 180 watts.
On the basis of the data obtained, it is possible to purchase a cable or electric mats for floor heating.
As for the wiring, it is necessary to calculate the total power of the devices that are used in the apartment. This information can be found instructions for the technique, and even duplicate it on the instrument housing.
The resulting total power must be adjusted by multiplying by a factor of 0.8. This is an amendment to the fact that all devices will not work in the apartment at the same time. Based on the data obtained from this table, you can determine the desired cross-section of the copper cable
Aluminum is not suitable for wiring a house where it is planned to install a floor heating system. This is because copper has better thermal conductivity. According to the table, you also need to determine the current strength and put the machines on the electricity meter.
If the wiring in the apartment does not meet the necessary characteristics, it must be replaced before installing the heating cable or mats. If this is not done, then the apartment will periodically turn off the electricity, and then the sockets will melt.
Ultimately, this will result in a short circuit and fire. This is dangerous and you should not save on security, especially if the house or apartment is made of combustible materials. We recommend that you familiarize yourself with the wiring diagrams in the apartment and the recommendations for installing it yourself. To do this, follow the link.
Installation of mats and installation of control system
The installation of electric mats is simpler and faster than installing a cable. It is enough to place them on the heating area, which was determined during the preparation of the scheme.
The cable will have to be laid on a mounting tape, which is a metal fastener that locks into the floor screed. When laying the cable, it is necessary to make turns of the same width
This will ensure a uniform level of floor heating. During installation, it is not recommended to break the cable.
After laying the cable, you need to install the thermostat. It performs an important function - maintaining a given floor temperature.
This allows you to reduce energy consumption, since periodically the heating will turn off when the set temperature is reached. If the temperature sensor detects a decrease in the user-defined mode, the heating will automatically turn on.
To mount the control unit in the wall, you need to drill a hole of the required diameter. There should be a source of electricity near the installation site of the unit. It could be a socket
The hole should be located above 30 cm from the floor surface. A vertical channel is drilled down from the hole where the corrugation for the temperature sensor will be installed.
The opposite end of the corrugation should be located between the turns of the heating cable at an equal distance. If this rule is not observed, then the sensor readings will be overestimated.
When connecting the heating cable to the control unit, follow the instructions from the equipment manufacturer. Before connecting, you need to check the resistance of the wires with a special device.
Rules for laying infrared warm floor
Despite the structural differences, the infrared floor heating is as easy to install as electric mats. But there is a difference between them. When connecting a film heater, a parallel connection is not used, but a series one.
From a structural point of view, this is a more reliable way, since if a module fails, the rest will continue to function.
Such a floor has the advantage, as it allows to reduce energy consumption due to its reduced consumption compared to electric mats. The film is sold in rolls and bought in the amount necessary for the heating area. The film can be cut, but only in those places where it is allowed by the manufacturer.
The film must be laid with a slight overlap, strictly following the markup. The modules are fastened together by molar tape. This is a temporary method of fastening, since after filling with a bulk floor, the need for fastening will disappear.
In more detail, we examined the features of the film type of heating in another article.
Installation Guide for Electric Underfloor Heating
The quality of the coating depends on the condition of the substrate on which it is to be laid. Work should begin with the dismantling of the old coating. Everything must be dismantled, including the old screed.
To work, you need a chipper. It is also necessary to think in advance how to transport and where to export the old concrete. Landfill is not permitted in landfills
After removing the old coating, all fine litter and dust must be removed. After that, you need to inspect the floor area and in the presence of cracks they must be repaired. When the floor surface is prepared, you can begin waterproofing and warming.
Stage # 1 - installation of insulation under the electric floor
It is necessary to lay a heater on the prepared base. Cork sheets are preferred. They have sufficient density and do not sag under the weight of the screed, as is the case with polystyrene foam.
The use of low-density insulation will lead to the need to dismantle the finished floor due to depreciation of the material.
Cheap polystyrene foam makes the screed crack under the tile. This inevitably leads to peeling and damage to the tiles. Small cracks appear first, and then the tiles peel off
The insulation is attached to the surface by gluing to bitumen mastic. Through the use of this material, not only fixation of cork sheets is achieved, but also waterproofing.
The durability of underfloor heating also depends on the quality of gluing. After waiting 5-6 hours, you can proceed to pouring screed. Screed thickness should be at least 3 cm.
When using a bulk floor, there is no need to align with the rule, as is the case with self-mixed cement mortars. After work, you need to leave the surface to dry completely, for about 3-4 days.
Stage # 2 - laying heating mats
After the solidification of the bulk solution, you can proceed with the installation of a warm floor under the tile. First you need to outline with chalk the places in which the mats will not be installed. This will help to navigate and not to overuse the material.
Image Gallery
Photo from
Rolling floor heating mats
Cutting mats at the turning point
Apply tile adhesive to the system
Flooring device
After installing the mats, you need to proceed with the installation of the control unit and the temperature sensor. The control unit must be connected in strict accordance with the scheme and color marking of the wires, which are provided by the manufacturer.
Down from the control unit, a special corrugation is laid where the temperature sensor will be installed. The end of the corrugation, which is located between the heating mats, must be tightly corked.
If this is not done, then when pouring, the solution will penetrate inside, harden and render the sensor unusable. In addition, the mixture frozen in the corrugation will make it difficult to replace the sensor
When the installation of electronics is completed, you need to turn on the system and check its performance. If there are no defects in the operation of the heating system, you can proceed with pouring the last layer of screed. The required fill level should be noted on the wall to make it easier to navigate.
The minimum thickness of the screed is 4 cm. During pouring of the self-leveling floor, it is necessary to monitor the uniform distribution of the liquid. You can use a roller to move excess solution.
After pouring, you need to wait a few days until completely dry. At this time, you need to control the temperature in the apartment. If the air is dry and hot, there is a risk of cracking the screed. Tile masonry can only be started after the bulk floor has completely dried.
Stage # 3 - cutting floor tiles
For work with a floor tile the manual tile cutter perfectly suits. To work with it, you need to prepare the tile in advance. The tile is pre-soaked if specified by the manufacturer.
If there are no such recommendations, then just wipe the tile with a damp cloth. This is necessary to clean the surface on which the cutting element of the tool will move.
You do not need to cut tiles in advance. This is done as necessary, since if the sides of the walls have a slight discrepancy, then the tile will have to be cut again
This is done as necessary, in places where the masonry approaches the wall or corner. If water or heating pipes come out of the floor, then there will be a need to make curly holes in the tile.
A hand torch is used for this. The holes made with it can have jagged edges.To eliminate the aesthetic defect, it is necessary to process the edges with sandpaper.
Stage # 4 - laying tiles on the heated floor
It is necessary to start work on tiling the floor with markings, which is largely determined by the type of masonry. The most common tile laying options are diagonal and straight.
Which way to choose depends on the interior design and geometric features of the room.
After marking, you need to dilute a small amount of glue in a container of water. The adhesive mixture must be heat-resistant. Glue is applied to the prepared base with a notched trowel. There should be no voids under the tiles, as these places will be vulnerable to the point pressure, which will render the tile unusable.
On top of the adhesive solution, tile is laid and leveled. It is periodically necessary to check for tilt. This is done using the construction level.
The level should not be longer than 60 cm, since with a longer length the error of the readings increases. In order to maintain an equal distance between the tiles, you must use plastic crosses.
Their standard size is 2 mm. If the tile is large, a larger size can be used. The crosses that regulate the height are removed, and those that border four tiles are not dismantled after masonry, but are hidden during grouting.
For grouting, special compositions are used, painted in the tone of the lined surface. Grouting can only be done after the adhesive has cured.
Stage # 5 - varnishing of the finished tile floor
To preserve the tile in its original form, you need to take care of varnishing. This simple procedure will prevent the need for tile replacement.
Especially varnishing is relevant for matte tiles, which are often used for the floor in the bathroom, since it does not slip.
Varnish should be applied with a flap of fabric that does not leave scraps of thread. When applying, avoid the appearance of bubbles and stripes. You need to start from the farthest corner of the room from the entrance
When the first layer of varnish is applied, it is necessary to open the window in the airing mode, and also close the door to the room. After complete drying, which occurs after 6-8 hours (depending on the composition of the varnish), it is necessary to repeat the procedure again.
How to mount the control unit:
How to lay a heated floor in rooms with small heat losses:
What will happen if you do not fix the insulation:
What to look for when designing a home:
Proper installation of underfloor heating systems for laying floor ceramics will significantly extend its life. It is necessary to carefully choose a manufacturer of heating systems.
Most often, electronics fail, which is easy to replace and continue to use underfloor heating. In the event of a breakdown of the control unit, it will be difficult to get a new one if the manufacturer ceases to produce heating systems. Temperature sensors are easier to pick up, as they are interchangeable in many models.
Have you installed underfloor heating in your home? Which heating system did you use? How satisfied are you with the result and have you encountered any type of breakdown? Share your experience of installation and operation of underfloor heating - leave your comments under this article.